What does a vehicle module power supply look like?(5)
Remote control switch circuit
The remote control switch operation of the module power supply is carried out through the REM terminal. There are two general control methods:
(1) REM is connected to -VIN (reference ground), the remote control is turned off, and VREF<0.4V is required. REM is suspended or connected to +VIN, the module works, and VREM>1V is required.
(2) REM is connected to VIN, the remote control is turned off, and VREM<0.4V is required. REM is connected to +VIN, the module works, VREM>1V is required. REM is suspended, and the remote control is turned off, that is, the so-called "suspended shutdown" (-R).
If the control is to be isolated from the input, an optocoupler can be used to pass the control signal
Regardless of how much control the product material and production process are, aging needs to be checked. Because the incoming inspection of electronic components and transformers is difficult to control, the quality stability of this batch of power supplies and whether the materials are detected to have potential safety hazards can only be detected through aging and high-temperature sampling of the entire batch of power supplies.